Town of Erie requires a minimum 110 mph sustained wind warranty from roof covering manufacturer.
- Ice shield is not required
- 3-Tab Shingles are not permitted on habitable structures
- Mid-roof inspections are not required
- Contractor is required to provide a ladder (set and secured) for final inspection
- Attic Ventilation shall comply with R806
- Drip edge is required on eaves and on rakes
- New roof coverings shall not be installed without first removing existing roof coverings
- Flashing shall comply with R908.6
- Sidewall flashing shall comply with R905.2.8.3
- Valleys shall comply with R905.2.8.2
- Underlayment shall comply with R905.1.1 (and tables)
- Low-slope roofs shall have minimum 2 layers of underlayment
- Fasteners shall be in accordance with code requirements for type of roofing to be installed
Code references are to the 2015 International Residential Code.